• DocumentCode
    1871650
  • Title

    Evaluation of the performance of dual chevron bluff body vortex flowmeters

  • Author

    Bentley, J.P. ; Benson, R.A. ; Jackson, R.S.

  • Author_Institution
    Teesside Univ., Middlesbrough, UK
  • fYear
    1996
  • fDate
    35173
  • Abstract
    Vortex flowmeters are less repeatable than turbine flow meters and the latter are normally preferred for high accuracy applications. One method of improving repeatability is to use two bluff bodies in series. Previous work has shown that certain combinations of two rectangular bluff bodies separated by a narrow gap give optimum repeatability. Features of using these bluff bodies suggest the use of chevron shaped bluff bodies. The results are presented of a wind tunnel evaluation of the vortex shedding performance of nine dual combinations based on six bluff body geometries for a range of separations between 3 and 15 mm
  • Keywords
    flowmeters; turbulence; vortices; 3 to 15 mm; 6 m/s; bluff bodies in series; chevron angle size; dual chevron bluff body; optimum repeatability; performance; repeatability improvement; vortex flowmeters; vortex shedding; wind tunnel evaluation;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Advances in Sensors for Fluid Flow Measurement, IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19960583
  • Filename
    543316