DocumentCode :
1874493
Title :
Bio-Particle Sorting Employing Hydrodynamic Rectification in a Microfluidic Circuit
Author :
Yamada, M. ; Seki, M.
Author_Institution :
The University of Tokyo, Tokyo, JAPAN
fYear :
2006
fDate :
2006
Firstpage :
54
Lastpage :
57
Abstract :
A microfluidic bio-particle sorter has been developed utilizing a concept that a microchannel network acts as a resistive circuit when a Newtonian fluid is continuously introduced into the network. By hydrodynamically rectifying the particle positions inside the microfluidic circuit, particles suspended in liquid are perfectly aligned onto one sidewall inside the microchannel, and then concentrated and sorted according to size. We used particles with diameter of 1~ 3 μm; they were concentrated 30~ 80-fold, and separated even when the difference in particle diameter was smaller than 1 μm. In addition, it was demonstrated that the distributed flow rates well corresponded to the theoretical values.
Keywords :
Cells (biology); Circuits; Electrostatic analysis; Fluid flow; Hydrodynamics; Intelligent networks; Microchannel; Microfluidics; Optical sensors; Sorting;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Micro Electro Mechanical Systems, 2006. MEMS 2006 Istanbul. 19th IEEE International Conference on
Conference_Location :
Istanbul, Turkey
ISSN :
1084-6999
Print_ISBN :
0-7803-9475-5
Type :
conf
DOI :
10.1109/MEMSYS.2006.1627734