• DocumentCode
    1876600
  • Title

    Experimental results of the ATF in-line injection system

  • Author

    Wang, X.J. ; Srinivasan-Rao, T. ; Batchelor, K. ; Babzien, M. ; Ben-Zvi, I. ; Malone, R. ; Pogorelsky, I. ; Qui, X. ; Sheehan, J. ; Skaritka, J.

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY, USA
  • Volume
    2
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    890
  • Abstract
    The initial experimental results of the Brookhaven accelerator test facility (ATF) in-line injector is presented. The ATF in-line injector employed a full copper RF gun with a pair of solenoid magnets for emittance compensation. The maximum acceleration field of the RF gun was measured to be 130 MV/m. The electron yield from the copper cathode was maximized using p-polarized laser and the Schottky effect. The quantum efficiency under optimum conditions was measured to be 0.04%. The measured electron bunch length was less than 11 ps, which agreed with the laser pulse length measurement using a streak camera. The normalized RMS emittance for 0.25 nC charge is 0.9±0.1 mm-mrad, which is almost four times smaller than the emittance predicted by the space-charge effect for a non-emittance compensation photocathode RF gun. The normalized RMS emittance for 0.6 nC charge was measured range from 1 to 3 mm-mrad. This measurement was first experimental demonstration of emittance compensation in a high-gradient, S-band photocathode RF gun
  • Keywords
    Schottky effect; accelerator RF systems; accelerator magnets; beam handling techniques; electron accelerators; electron guns; electron sources; particle beam diagnostics; particle beam injection; particle sources; photocathodes; solenoids; space charge; ATF in-line injection system; Brookhaven accelerator test facility; Cu; Schottky effect; electron bunch length; electron yield; emittance compensation; high-gradient S-band photocathode RF gun; laser pulse length measurement; maximum acceleration field; normalized RMS emittance; p-polarized laser; quantum efficiency; solenoid magnets pair; space-charge effect; streak camera; Cathodes; Copper; Electrons; Length measurement; Life estimation; Magnetic field measurement; Pulse measurements; Radio frequency; Solenoids; Test facilities;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505072
  • Filename
    505072