• DocumentCode
    1877814
  • Title

    Development of an accelerator-ready photocathode drive laser at CEBAF

  • Author

    Benson, S. ; Shinn, M.

  • Author_Institution
    Continuous Electron Beam Accel. Facility, Newport News, VA, USA
  • Volume
    2
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    1052
  • Abstract
    Many injector designs for free-electron lasers and linear colliders use photocathode sources in lieu of a thermionic cathode. These designs require mode-locked lasers with very tight phase and amplitude jitter specifications to achieve the electron beam quality needed for these applications. We have characterized the long term stability of a mode-locked laser for use in the injector test stand at CEBAF. The sources of drift and instabilities were studied and characterized. Initial results indicate that the most important source of drift is a change in the effective cavity length. A possible design for automatically optimizing the length is presented
  • Keywords
    colliding beam accelerators; electron accelerators; electron beams; electron sources; free electron lasers; jitter; laser cavity resonators; laser mode locking; laser stability; linear colliders; particle beam injection; particle sources; photocathodes; CEBAF; FEL; accelerator-ready photocathode drive laser; amplitude jitter specifications; drift source; electron beam quality; free-electron lasers; injector designs; injector test stand; laser cavity length; linear colliders; long term stability; mode-locked lasers; phase jitter specifications; photocathode sources; Acceleration; Cathodes; Design optimization; Electron beams; Free electron lasers; Jitter; Laser mode locking; Laser stability; Optical design; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505126
  • Filename
    505126