Abstract :
This paper presents a comparative study of high-frequency (HF) voltage signal injections used for rotor position estimation in sensorless control of AC motors. This work reviews these methods and evaluates the performance under sensorless speed control applied to a surface permanent-magnet synchronous motor (PMSM). Theoretical analysis is verified by simulations and confirms the effectiveness of these methods. The experimental results of speed control using an industrial PMSM drive system are presented for each of the injection methods.
Keywords :
angular velocity control; machine control; permanent magnet motors; sensorless machine control; signal processing; synchronous motor drives; HF signal injection methods; PM synchronous motors; high-frequency voltage signal injection method; industrial PMSM drive system; rotor position estimation; sensorless speed control; surface permanent-magnet synchronous motor; theoretical analysis; Bandwidth; Hafnium; Pulse width modulation; Rotors; Sensorless control; Space vector pulse width modulation; Synchronous motors; Torque control; Velocity control; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition (APEC), 2010 Twenty-Fifth Annual IEEE
Conference_Location :
Palm Springs, CA
ISSN :
1048-2334
Print_ISBN :
978-1-4244-4782-4
Electronic_ISBN :
1048-2334
Type :
conf
DOI :
10.1109/APEC.2010.5433506
Filename :
5433506
Link To Document :
بازگشت