Title :
Fermilab Main Injector abort kicker system
Author :
Jensen, C.C. ; Dinkel, J.A.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Abstract :
The Fermilab Main Injector will require an updated abort kicker system. A new modulator and modified magnet are required to meet the new requirements. Two Main Ring abort magnets will be modified to contain a 12.5 Ω load resistor in series with the existing magnet. A pulse transformer is used with a 3.1 Ω, 10 μs pulse forming network to reduce the capacitor voltage to 34 kV and allow operation in air. The pulse transformer primary is floated to allow grounded cathode operation of the thyratron and a grounded terminal on the pulse forming network capacitors
Keywords :
accelerator magnets; electromagnets; particle beam injection; power supplies to apparatus; proton accelerators; pulse transformers; synchrotrons; thyratrons; 10 mus; 12.5 ohm; 3.1 ohm; 34 kV; Fermilab Main Injector abort kicker system; Main Ring abort magnets; capacitor voltage reduction; grounded cathode operation; grounded terminal; load resistor; modified magnet; modulator; pulse forming network capacitors; pulse transformer; pulse transformer primary; thyratron; Capacitors; Circuits; Impedance; Inductance; Magnetic modulators; Magnetic resonance; Magnetosphere; Power cables; Pulse transformers; Snubbers;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505186