DocumentCode
1879495
Title
Fermilab Main Injector abort kicker system
Author
Jensen, C.C. ; Dinkel, J.A.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume
2
fYear
1995
fDate
1-5 May 1995
Firstpage
1239
Abstract
The Fermilab Main Injector will require an updated abort kicker system. A new modulator and modified magnet are required to meet the new requirements. Two Main Ring abort magnets will be modified to contain a 12.5 Ω load resistor in series with the existing magnet. A pulse transformer is used with a 3.1 Ω, 10 μs pulse forming network to reduce the capacitor voltage to 34 kV and allow operation in air. The pulse transformer primary is floated to allow grounded cathode operation of the thyratron and a grounded terminal on the pulse forming network capacitors
Keywords
accelerator magnets; electromagnets; particle beam injection; power supplies to apparatus; proton accelerators; pulse transformers; synchrotrons; thyratrons; 10 mus; 12.5 ohm; 3.1 ohm; 34 kV; Fermilab Main Injector abort kicker system; Main Ring abort magnets; capacitor voltage reduction; grounded cathode operation; grounded terminal; load resistor; modified magnet; modulator; pulse forming network capacitors; pulse transformer; pulse transformer primary; thyratron; Capacitors; Circuits; Impedance; Inductance; Magnetic modulators; Magnetic resonance; Magnetosphere; Power cables; Pulse transformers; Snubbers;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location
Dallas, TX
Print_ISBN
0-7803-2934-1
Type
conf
DOI
10.1109/PAC.1995.505186
Filename
505186