DocumentCode :
1879544
Title :
Maximum efficiency point tracking (MEPT) method and dead time control
Author :
Abu-Qahouq, Jaber A. ; Mao, Hong ; Al-Atrash, H.J. ; Batarseh, Lssa
Author_Institution :
Sch. of Electr. Eng. & Comput. Sci., Central Florida Univ., Orlando, FL, USA
Volume :
5
fYear :
2004
fDate :
20-25 June 2004
Firstpage :
3700
Abstract :
Adaptive control method, to be called Maximum Efficiency Point Tracking (MEPT), is presented in this paper. This method tracks the system efficiency, which is a DC-DC converter here, and optimizes adaptively system parameters to maximize the efficiency. MEPT method is used in this paper to optimize the primary-to-secondary switches dead time parameter in an isolated topology to prevent switches body diodes conduction during freewheeling periods and reduces body diodes conduction related losses in order to improve the efficiency. MEPT tracks the converter efficiency while changing the dead time and detects the optimized dead time value at the maximum efficiency point at different load and line conditions. In this paper, the MEPT method is discussed, analyzed, and digital control algorithm and implementation are presented.
Keywords :
DC-DC power convertors; adaptive control; digital control; optimisation; power semiconductor diodes; power semiconductor switches; DC-DC converter; adaptive control method; adaptive system parameters; converter efficiency; dead time control; digital control algorithm; diode conduction; freewheeling periods; isolated topology; losses; maximum efficiency point tracking method; optimization; Adaptive control; Analog-digital conversion; Control systems; DC-DC power converters; Digital control; Diodes; Power electronics; Switches; Temperature; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual
ISSN :
0275-9306
Print_ISBN :
0-7803-8399-0
Type :
conf
DOI :
10.1109/PESC.2004.1355130
Filename :
1355130
Link To Document :
بازگشت