  • Abstract
    A superconducting focusing solenoid for X-band klystron has been developed. The system consists of a conduction cooled NbTi solenoid, high Tc superconductor current leads, and a GM refrigerator. The GM refrigerator can cool down the solenoid from the room temperature to below 4 Kelvin by 4 days. This allow us to operate the system without supplying any cryogen such as liquid helium or nitrogen. The solenoid produces a desired field profile whose maximum value is about 7 kGauss. A normal conducting bucking coil is also implemented in order to tune the field at the cathode. Cool down tests performed at MELCO, KEK, and SLAC confirmed that the system can be cooled down by 4 days. Field measurements performed at those places confirmed that the field profile is very stable between thermal cycles
  • Keywords
    accelerator RF systems; accelerator cavities; klystrons; superconducting cavity resonators; 7 kG; GM refrigerator; NbTi; X-band klystron; conduction cooled NbTi solenoid; field profile; high Tc superconductor current leads; normal conducting bucking coil; superconducting focusing solenoid; Helium; Kelvin; Klystrons; Niobium compounds; Nitrogen; Performance evaluation; Refrigeration; Solenoids; Temperature; Titanium compounds;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505237
  • Filename
    505237