• DocumentCode
    1885333
  • Title

    Design and testing of a high power, ultra-high vacuum, dual-directional coupler for the Advanced Photon Source (APS) linear accelerator

  • Author

    Brauer, S.O. ; Grelick, A.E. ; Grimmer, J. ; Otocki, R.D. ; Kang, Y.W. ; Noonan, J. ; Russell, T.

  • Author_Institution
    Adv. Photon Source, Argonne Nat. Lab., IL, USA
  • Volume
    3
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    2020
  • Abstract
    Leaks and cracks have developed in the vacuum windows of the linac WR 284 waveguide directional couplers. In the existing coupler design the vacuum window is brazed to the waveguide. Replacement of a cracked window requires the removal of the component from the waveguide system resulting in a loss of vacuum in the waveguide. A new design has been developed and a prototype tested that utilizes bolted-in vacuum windows and allows for easier replacement of the windows in the system, while still providing suitable radio-frequency specifications
  • Keywords
    accelerator RF systems; accelerator cavities; directional couplers; electron accelerators; APS linear accelerator; Advanced Photon Source; RF specification; WR 284 waveguide directional couplers; bolted-in vacuum windows; design; high power ultra-high vacuum dual-directional coupler; testing; vacuum windows; waveguide system; Directional couplers; Flanges; Frequency; Klystrons; Linear particle accelerator; Prototypes; Space vector pulse width modulation; Testing; Vacuum systems; Waveguide components;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505438
  • Filename
    505438