• DocumentCode
    1885461
  • Title

    Cryogenic thermometry in superconducting accelerators

  • Author

    Datksov, V.I. ; Demko, J.A. ; Weisend, J.G. ; Hentges, M.

  • Author_Institution
    JINR, Dubna, Russia
  • Volume
    3
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    2034
  • Abstract
    The cryogenic thermometers used in superconducting accelerators must function over a temperature range of 1.5-300 K in very harsh environments that must be endured for the life of the accelerator. The authors prescribe requirements for cryogenic thermometers in accelerator installations. Thermometer mounting fixtures used in the Joint Institute for Nuclear Research “Nuclotron” (JINR, Dubna, Russia) and the Superconducting Super Collider (SSCL, Dallas, Texas, USA) are described. Experimental results for long-term stability of some cryogenic thermometers and basic recommendations for applications in large superconducting accelerator systems are given
  • Keywords
    low-temperature techniques; particle accelerator accessories; 1.5 to 300 K; Nuclotron; SSCL; Superconducting Super Collider; cryogenic thermometry; long-term stability; superconducting accelerators; thermometer mounting fixtures; Acceleration; Accelerator magnets; Costs; Cryogenics; Dielectrics and electrical insulation; Ionizing radiation; Superconducting magnets; Temperature distribution; Temperature measurement; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505443
  • Filename
    505443