Cryogenic thermometry in superconducting accelerators
Author
Datksov, V.I. ; Demko, J.A. ; Weisend, J.G. ; Hentges, M.
Author_Institution
JINR, Dubna, Russia
Volume
3
fYear
1995
fDate
1-5 May 1995
Firstpage
2034
Abstract
The cryogenic thermometers used in superconducting accelerators must function over a temperature range of 1.5-300 K in very harsh environments that must be endured for the life of the accelerator. The authors prescribe requirements for cryogenic thermometers in accelerator installations. Thermometer mounting fixtures used in the Joint Institute for Nuclear Research “Nuclotron” (JINR, Dubna, Russia) and the Superconducting Super Collider (SSCL, Dallas, Texas, USA) are described. Experimental results for long-term stability of some cryogenic thermometers and basic recommendations for applications in large superconducting accelerator systems are given
Keywords
low-temperature techniques; particle accelerator accessories; 1.5 to 300 K; Nuclotron; SSCL; Superconducting Super Collider; cryogenic thermometry; long-term stability; superconducting accelerators; thermometer mounting fixtures; Acceleration; Accelerator magnets; Costs; Cryogenics; Dielectrics and electrical insulation; Ionizing radiation; Superconducting magnets; Temperature distribution; Temperature measurement; Voltage;