Title :
Pressure measurement for the UNK-1 vacuum system
Author :
Kiver, A. ; Komarov, V. ; Mirzoev, K. ; Terekhov, V. ; Vasilevsky, A.
Author_Institution :
IHEP, Protvino, Russia
Abstract :
The required vacuum 10-9 Torr at the UNK-1 will be produced by 3900 ion pumps. For pressure measurement in the 10-5 -10-9 Torr range the system based on continuous monitoring of all ion pumps currents is being developed as a part of vacuum instrumentation. To cover such a range current-to-frequency converters are used as current monitors. Their outputs pass to the acquisition electronics packaged into Eurocard style. Crates are distributed over 14 surface buildings. This presentation focuses on the measurement principle and the major electronics components
Keywords :
electric current measurement; pressure measurement; proton accelerators; storage rings; synchrotrons; vacuum apparatus; 0.000000001 to 0.00001 torr; Eurocard; UNK-1; acquisition electronics; current monitors; current-to-frequency converters; ion pumps; pressure measurement; vacuum system; Clocks; Current measurement; Diodes; Frequency conversion; Hardware; Instruments; Monitoring; Power supplies; Pressure measurement; Vacuum systems;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505445