DocumentCode :
1887967
Title :
A microstrip based position system for the alignment of the TTF cryostat
Author :
Giove, D. ; Bosotti, A. ; Pagani, C. ; Varisco, G.
Author_Institution :
Istituto Nazionale di Fisica Nucl., Milano, Italy
Volume :
4
fYear :
1995
fDate :
1-5 May 1995
Firstpage :
2093
Abstract :
The cryostat designed for the superconducting cavities of the Tesla Test Facility (TTF) is quite a complex structure with strict requirements on the alignment of the different components at the LHe temperature. A system able to measure on-line misalignments on the full length of the cryostat module (12 meters long) during cool down and operation procedures seems a very useful tool in order to verify structural analysis computation. A microstrip based system using a stretched wire has been designed for this purpose in our laboratory. DESY will provide the stretching system for the wire and the support system for the position transducers. In this paper we will present and discuss the design based on warm and cold tests on a prototype
Keywords :
accelerator cavities; cryostats; particle beam diagnostics; position sensitive particle detectors; superconducting cavity resonators; test facilities; 4.2 K; LHe temperature; TTF cryostat alignment; Tesla Test Facility; cold tests; microstrip based position system; on-line misalignments; position transducers; stretched wire; structural analysis computation; superconducting cavities; warm tests; Assembly systems; Helium; Microstrip; Radio frequency; Stripline; Superconducting magnets; Temperature; Testing; Transducers; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
Type :
conf
DOI :
10.1109/PAC.1995.505465
Filename :
505465
Link To Document :