• DocumentCode
    1889046
  • Title

    Calibration and error analysis of a Ka-band fully polarimetric radiometer built with wideband microstrip correlator

  • Author

    Wang, Xinbiao ; Li, Jing ; Jiang, Jingshan

  • Author_Institution
    Center for Space Sci. & Appl. Res., Beijing, China
  • fYear
    2011
  • fDate
    24-29 July 2011
  • Firstpage
    2229
  • Lastpage
    2232
  • Abstract
    In this paper we present calibration and error analysis of our Ka-band fully polarimetric radiometer, the radiometer used a wideband microstrip correlator. The calibration method is based on the tri-polarimetric calibration technique of Gasiewski and Kunkee, but is extended to provide the calibration of the fourth Stokes parameter using a retarder plate. A method to determine the phase shift of the retarder plate is introduced, a calibration matrix inversion technique is described as well. The calibration uncertainties and calibration error analysis are discussed at last.
  • Keywords
    calibration; correlators; error analysis; geophysical equipment; polarimetry; radiometers; calibration error analysis; calibration matrix inversion; calibration uncertainty; fourth Stokes parameter; fully polarimetric radiometer; retarder plate; tripolarimetric calibration; wideband microstrip correlator; Calibration; Correlators; Microstrip; Microwave measurements; Microwave radiometry; Microwave theory and techniques; Uncertainty; Fully polarimetric radiometer; calibration; error analysis; microstrip correlator; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Geoscience and Remote Sensing Symposium (IGARSS), 2011 IEEE International
  • Conference_Location
    Vancouver, BC
  • ISSN
    2153-6996
  • Print_ISBN
    978-1-4577-1003-2
  • Type

    conf

  • DOI
    10.1109/IGARSS.2011.6049612
  • Filename