DocumentCode
1892295
Title
Partial discharge characteristics of enamelled wire under high-frequency voltage stress-approaches for short-time testing
Author
Paede, M. ; Pfeiffer, W.
Author_Institution
Lab. of Electr. Meas. Technol., Technische Hochschule Darmstadt, Germany
fYear
2001
fDate
2001
Firstpage
17
Lastpage
21
Abstract
A possibility to compare the quality of different insulation materials with respect to high-frequency voltage stress is to compare the partial discharge (PD) characteristics at high-frequency voltages (here at 100 kHz and 1 MHz). One indicator for the quality is the PD inception voltage (PDIV). Another one is the ´lifetime´ of the insulation stressed with PD at high-frequency voltage. In this paper measurements with different approaches on enamelled wire are described. The results and special characteristics of the tests are compared and discussed
Keywords
insulated wires; insulation testing; partial discharge measurement; 1 MHz; 100 kHz; PD inception voltage; enamelled wire; high-frequency voltage stress; partial discharge characteristics; short-time testing; Frequency conversion; Frequency measurement; Insulation testing; Partial discharge measurement; Partial discharges; Stress; Switched-mode power supply; Variable speed drives; Voltage; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 2001. Proceedings
Conference_Location
Cincinnati, OH
ISSN
0362-2479
Print_ISBN
0-7803-7180-1
Type
conf
DOI
10.1109/EEIC.2001.965583