• DocumentCode
    1892295
  • Title

    Partial discharge characteristics of enamelled wire under high-frequency voltage stress-approaches for short-time testing

  • Author

    Paede, M. ; Pfeiffer, W.

  • Author_Institution
    Lab. of Electr. Meas. Technol., Technische Hochschule Darmstadt, Germany
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    17
  • Lastpage
    21
  • Abstract
    A possibility to compare the quality of different insulation materials with respect to high-frequency voltage stress is to compare the partial discharge (PD) characteristics at high-frequency voltages (here at 100 kHz and 1 MHz). One indicator for the quality is the PD inception voltage (PDIV). Another one is the ´lifetime´ of the insulation stressed with PD at high-frequency voltage. In this paper measurements with different approaches on enamelled wire are described. The results and special characteristics of the tests are compared and discussed
  • Keywords
    insulated wires; insulation testing; partial discharge measurement; 1 MHz; 100 kHz; PD inception voltage; enamelled wire; high-frequency voltage stress; partial discharge characteristics; short-time testing; Frequency conversion; Frequency measurement; Insulation testing; Partial discharge measurement; Partial discharges; Stress; Switched-mode power supply; Variable speed drives; Voltage; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 2001. Proceedings
  • Conference_Location
    Cincinnati, OH
  • ISSN
    0362-2479
  • Print_ISBN
    0-7803-7180-1
  • Type

    conf

  • DOI
    10.1109/EEIC.2001.965583
  • Filename
    965583