• DocumentCode
    1892976
  • Title

    SamicaShield(R) insulation system for frequency-converter-driven low-voltage three-phase motors. SamicaFirewall(R) insulation system for low-voltage three-phase motors (smoke-dissipating motors)

  • Author

    Brandes, H. ; Partzsch, T. ; Klotsche, H. ; Speck, J.

  • fYear
    2001
  • fDate
    2001
  • Firstpage
    195
  • Lastpage
    198
  • Abstract
    The requirements of today´s modern drive techniques are mainly met by the application of converter-driven low-voltage induction motors. Fast switching inside the converter creates traveling waves in the cables between the converter and the motor. The hereby occurring voltage loads strongly harm the winding insulation, which may result in a premature failure. Partial discharge measurements and long-term tests were carried out with an improved insulation system, which is introduced in the paper
  • Keywords
    induction motor drives; insulation testing; machine insulation; machine windings; partial discharge measurement; SamicaFirewall insulation system; SamicaShield insulation system; cables; converter; fast switching; frequency-converter-driven motors; induction motors; insulation system; low-voltage three-phase motors; partial discharge measurements; premature failure; smoke-dissipating motors; traveling waves; voltage loads; winding insulation; Cable insulation; Cables; Filters; Frequency; Induction motors; Insulation testing; Protection; Switching converters; System testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 2001. Proceedings
  • Conference_Location
    Cincinnati, OH
  • ISSN
    0362-2479
  • Print_ISBN
    0-7803-7180-1
  • Type

    conf

  • DOI
    10.1109/EEIC.2001.965609
  • Filename
    965609