Abstract
The requirements of today´s modern drive techniques are mainly met by the application of converter-driven low-voltage induction motors. Fast switching inside the converter creates traveling waves in the cables between the converter and the motor. The hereby occurring voltage loads strongly harm the winding insulation, which may result in a premature failure. Partial discharge measurements and long-term tests were carried out with an improved insulation system, which is introduced in the paper
Keywords
induction motor drives; insulation testing; machine insulation; machine windings; partial discharge measurement; SamicaFirewall insulation system; SamicaShield insulation system; cables; converter; fast switching; frequency-converter-driven motors; induction motors; insulation system; low-voltage three-phase motors; partial discharge measurements; premature failure; smoke-dissipating motors; traveling waves; voltage loads; winding insulation; Cable insulation; Cables; Filters; Frequency; Induction motors; Insulation testing; Protection; Switching converters; System testing; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 2001. Proceedings
Conference_Location
Cincinnati, OH
ISSN
0362-2479
Print_ISBN
0-7803-7180-1
Type
conf
DOI
10.1109/EEIC.2001.965609
Filename
965609
Link To Document