• DocumentCode
    1893215
  • Title

    Secondary arc extinction of single pole auto-reclosing on EHV transmission lines with shunt compensation reactors

  • Author

    Babu, G. ; Ramesh, Maneesha Vinodini

  • Author_Institution
    Dept. of Electr. & Electron. Eng., P.V.P. Siddhartha Inst. of Technol., Vijayawada, India
  • fYear
    2012
  • fDate
    13-15 Dec. 2012
  • Firstpage
    52
  • Lastpage
    58
  • Abstract
    To study the effect of line compensating reactors on EHV lines in successfully clearing the transitory single line to ground (SLG) faults by SPAR (Single pole auto re-closer). The main purpose of this project is to obtain and validate a robust model of the primary and secondary arcs in a transmission line to clearing single line to ground faults by means of single phase reclosing was investigated. Neutral reactor for the line connected shunt reactor banks were optimizing sustained values of secondary arc fault current and post fault recovery voltage. This paper addresses shunt compensation as it affects single phase reclosing procedure. The work will illustrate transient study of single phase reclosing of the 400kv Transmission system. This project mainly concentrates on the application of Shunt Reactors for secondary arc extinction in high voltage lines after single-pole switching is investigated. The study has used PSCAD (EMTP) simulation to determine the behaviour of the system response to switching operation. The successful single phase reclosing is investigated by conducting fault clearing and reclosing cases utilizing dynamic arc model. The PSCAD software tool is using for analyzing secondary arc extinction phenomenon in EHV lines.
  • Keywords
    arcs (electric); fault currents; power transmission faults; power transmission lines; reactors (electric); EHV transmission lines; EMTP simulation; PSCAD software tool; SLG fault; SPAR; fault recovery voltage; line connected shunt reactor banks; primary arcs; robust model; secondary arc extinction; secondary arc fault current; shunt compensation reactor; single line to ground fault; single pole auto-reclosing; single-pole switching; Arc Model; Neutral Grounding Reactor (NGR); PSCAD; Secondary arc Extinction; Single Pole Auto-Reclosing (SPAR);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Emerging Trends in Electrical Engineering and Energy Management (ICETEEEM), 2012 International Conference on
  • Conference_Location
    Chennai
  • Print_ISBN
    978-1-4673-4633-7
  • Type

    conf

  • DOI
    10.1109/ICETEEEM.2012.6494443
  • Filename
    6494443