Title :
Response of ramp test to delamination in stator groundwall insulation
Author :
McDermid, W. ; Bromley, J.C.
Author_Institution :
Manitoba Hydro, Winnipeg, Man., Canada
Abstract :
High direct voltage ramp tests incorporating a continuous record of current versus voltage are known to be a sensitive indicator of groundwall cracks and fissures. Such defects often result in an obvious avalanche in the leakage current. Recently a different current versus voltage pattern has been associated with internal delamination. This paper reviews the evidence of this condition using ramp tests and partial discharge measurements on stator coils that are known to be delaminated between the groundwall and the turns to a greater or lesser extent
Keywords :
coils; delamination; electric machines; insulation testing; machine insulation; machine testing; partial discharge measurement; stators; current versus voltage pattern; groundwall cracks; groundwall fissures; high-direct voltage ramp test response; leakage current avalanche; partial discharge measurements; stator coils; stator groundwall insulation delamination; Circuit testing; Coils; Delamination; Humidity; Insulation testing; Partial discharges; Stators; Temperature; Time measurement; Voltage;
Conference_Titel :
Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 2001. Proceedings
Conference_Location :
Cincinnati, OH
Print_ISBN :
0-7803-7180-1
DOI :
10.1109/EEIC.2001.965646