DocumentCode
1894518
Title
Enhanced control scheme for three-phase/three-level rectifiers at partial load
Author
Ide, P. ; Schafmeister, F. ; Fröhleke, N. ; Grotstollen, H.
Author_Institution
DELTA Energy Syst. GmbH, Coesterweg, Germany
Volume
1
fYear
2004
fDate
20-25 June 2004
Firstpage
207
Abstract
A prominent boost-type three-level topology, which proved to represent a cost effective and highly efficient solution for switched mode rectifiers is inspected towards its operation at discontinuous conduction mode (DCM). This mode of operation occurs not only at high input voltage in conjunction with low load currents but even at medium loading in the vicinity of mains voltage zero crossings. And since the requirements on THD conflict with the actual behavior of the circuit when operated at DCM measures are needed for optimization. A detailed analysis of DCM and associated states is performed. Basic rules for the location of error voltages can be found. This leads to a novel measure to optimize the modulation and control scheme respectively, facilitating designs without additional inductance. Selected simulation and measurement results prove the enhanced modulation scheme.
Keywords
harmonic distortion; optimisation; power conversion harmonics; rectifying circuits; switching convertors; THD; boost-type three-level topology; discontinuous conduction mode; enhanced control; enhanced modulation scheme; error voltages; load currents; optimization; partial load; switched mode rectifiers; three-phase/three-level rectifiers; total harmonic distortion; Circuit topology; Control systems; Costs; Current control; Drives; Power electronics; Rectifiers; Switching frequency; Telecommunication switching; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual
ISSN
0275-9306
Print_ISBN
0-7803-8399-0
Type
conf
DOI
10.1109/PESC.2004.1355743
Filename
1355743
Link To Document