Total dose environment in SSR component on board Tsubasa (MDS-1) Satellite
Author
Kimoto, Yugo ; Ichikawa, Satoshi ; Sasada, Takeshi ; Koshiishi, Hideki ; Matsumoto, Haruhisa ; Goka, Tateo
Author_Institution
Japanese Aerosp. Exploration Agency, Tsukuba
fYear
2005
fDate
19-23 Sept. 2005
Abstract
Total dose data in solid-state recorder (SSR) component on board Tsubasa (MDS-1) satellite, flying in a highly eccentric orbit, is analyzed. 14 small dosimeters using RADFET were arranged in different shielding positions of the SSR component The initial total dose data in these positions are presented.
Keywords
artificial satellites; dosimetry; SSR component; Tsubasa satellite; dosimeters; eccentric orbit; solid-state recorder; total dose environment; Extraterrestrial measurements; Instruments; Magnetic sensors; Readout electronics; Satellites; Solid state circuits; Space missions; Space shuttles; Space technology; Space vehicles;