• DocumentCode
    1895323
  • Title

    An experimental setup for validating a CFD model of a double-sided PCB in a sealed enclosure at various power configurations

  • Author

    Johansson, Jonas ; Belov, Ilja ; Leisner, Peter

  • Author_Institution
    SaabTech AB, Jonkoping, Sweden
  • fYear
    2005
  • fDate
    18-20 April 2005
  • Firstpage
    127
  • Lastpage
    133
  • Abstract
    A flexible experimental setup enabling power control of a fully populated double-sided PCB has been realized, and is described in detail. A CFD model of a double-sided PCB housed in a sealed enclosure has been validated in a 19°C environment by means of temperature and flow measurement. The difference between simulated and measured component temperatures has been within 10%. Potential errors both in the model and in the experiments have been discussed and their impact on temperatures has been numerically evaluated.
  • Keywords
    computational fluid dynamics; finite volume methods; power electronics; printed circuit testing; printed circuits; reliability; thermal management (packaging); 19 C; CFD simulations; COTS components; double-sided PCB; flow measurement; power configurations; power control; power dissipation; sealed enclosure; temperature measurement; Aerospace electronics; Computational fluid dynamics; Computational modeling; Computer simulation; Cooling; Fluid flow measurement; Plastics; Power engineering and energy; Temperature measurement; Thermal management;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Thermal, Mechanical and Multi-Physics Simulation and Experiments in Micro-Electronics and Micro-Systems, 2005. EuroSimE 2005. Proceedings of the 6th International Conference on
  • Print_ISBN
    0-7803-9062-8
  • Type

    conf

  • DOI
    10.1109/ESIME.2005.1502787
  • Filename
    1502787