Title :
Charge balancing fill rate monitor
Author :
Rothman, J.L. ; Blum, E.B.
Author_Institution :
Nat. Synchrotron Light Source, Brookhaven Nat. Lab., Upton, NY, USA
Abstract :
A fill rate monitor has been developed for the NSLS storage rings to allow machine tuning over a very large dynamic range of beam current. Synchrotron light, focused on a photodiode, produces a signal proportional to the beam current. A charge balancing circuit processes the diode current, creating an output signal proportional to the current injected into the ring. The unit operates linearly over a dynamic range of 120 dB and can resolve pulses of injected beam as small as 1 μA
Keywords :
circuit tuning; electron accelerators; monitoring; particle beam diagnostics; particle beam injection; storage rings; 1 muA; 120 dB; NSLS storage rings; beam current; charge balancing circuit; charge balancing fill rate monitor; injected beam; machine tuning; photodiode; synchrotron light; Circuit optimization; Condition monitoring; Diodes; Dynamic range; Particle beam injection; Photodiodes; Signal processing; Signal resolution; Storage rings; Synchrotrons;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505580