Title :
An sampling detector for the RHIC BPM electronics
Author :
Ryan, W.A. ; Shea, T.J.
Author_Institution :
Brookhaven Nat. Lab., Upton, NY, USA
Abstract :
The analog detector electronics for the RHIC BPM Instrumentation is described. The detector employs a self-triggered peak detection algorithm for single bunch acquisition of beam position. Optimization of the design for low noise gives excellent position resolution, an internal self-calibration system insures position accuracy to well within the RHIC instrumentation system specification, and switched attenuation and gain insures very broad dynamic range. Design history, current implementation, and test results are described
Keywords :
analogue processing circuits; calibration; detector circuits; nuclear electronics; particle beam diagnostics; peak detectors; position sensitive particle detectors; signal sampling; RHIC; analog detector electronics; beam position; beam position monitor; dynamic range; electronics; gain; position resolution; self-calibration; self-triggered peak detection algorithm; single bunch acquisition; switched attenuation; Attenuation; Band pass filters; Detectors; Dynamic range; Instruments; Narrowband; RF signals; Radio frequency; Sampling methods; Switches;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505582