An sampling detector for the RHIC BPM electronics
Author
Ryan, W.A. ; Shea, T.J.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
Volume
4
fYear
1995
fDate
1-5 May 1995
Firstpage
2455
Abstract
The analog detector electronics for the RHIC BPM Instrumentation is described. The detector employs a self-triggered peak detection algorithm for single bunch acquisition of beam position. Optimization of the design for low noise gives excellent position resolution, an internal self-calibration system insures position accuracy to well within the RHIC instrumentation system specification, and switched attenuation and gain insures very broad dynamic range. Design history, current implementation, and test results are described
Keywords
analogue processing circuits; calibration; detector circuits; nuclear electronics; particle beam diagnostics; peak detectors; position sensitive particle detectors; signal sampling; RHIC; analog detector electronics; beam position; beam position monitor; dynamic range; electronics; gain; position resolution; self-calibration; self-triggered peak detection algorithm; single bunch acquisition; switched attenuation; Attenuation; Band pass filters; Detectors; Dynamic range; Instruments; Narrowband; RF signals; Radio frequency; Sampling methods; Switches;