DocumentCode
1895720
Title
RHIC beam position monitor characterization
Author
Cameron, P.R. ; Grau, M.C. ; Morvillo, M. ; Shea, T.J. ; Sikora, R.E.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
Volume
4
fYear
1995
fDate
1-5 May 1995
Firstpage
2458
Abstract
Techniques and results of RHIC BPM measurements are presented. These include wire scanner measurements of uncalibrated and calibrated BPM position and roll accuracy, preliminary measurements of the coupling between adjacent striplines to permit in situ offset calibration of the BPM signal cables and electronics, frequency dependence of the location of the BPM electrical center, and antenna measurements of the installed position of the electrical center relative to the cryostat fudicials. We also present results of simulations and measurements of cryogenic signal cable heating, and testing of the cryogenic feedthrus
Keywords
cables (electric); calibration; cryogenics; particle beam diagnostics; RHIC; antenna measurements; beam position monitor; cryogenic feedthrus; cryogenic signal cable heating; cryostat fudicials; electrical center; frequency dependence; position and roll accuracy; roll accuracy; wire scanner measurement; Antenna measurements; Cables; Calibration; Cryogenics; Electric variables measurement; Frequency measurement; Monitoring; Position measurement; Stripline; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location
Dallas, TX
Print_ISBN
0-7803-2934-1
Type
conf
DOI
10.1109/PAC.1995.505583
Filename
505583
Link To Document