Abstract :
Grid-flux (or grid-voltage)-oriented rotor current control of the doubly-fed induction generator is investigated in this paper. It is shown that by using a grid-flux-oriented system, the stability and damping of the system is independent of the d component of the rotor current, in contrast to a stator-flux-oriented system. Also for the stator-flux-oriented system, a certain value of the d component of the rotor current causes the system to become unstable. Hence, with a grid-flux-oriented system it is possible to produce as much reactive power as desired from a stability point of view. The theoretical results are verified experimentally with good result.
Keywords :
asynchronous generators; damping; electric current control; machine vector control; magnetic flux; reactive power; rotors; stability; stators; damping system; doubly-fed induction generators; grid-flux-oriented system; reactive power; rotor current control; stability point; stator-flux-oriented system; Current control; Damping; Electric current control; Frequency; Inductance; Induction generators; Rotors; Stability analysis; Stators; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 2004. PESC 04. 2004 IEEE 35th Annual
ISSN :
0275-9306
Print_ISBN :
0-7803-8399-0
Type :
conf
DOI :
10.1109/PESC.2004.1355793
Filename :
1355793
Link To Document :
بازگشت