• DocumentCode
    1896339
  • Title

    Development of beam position monitors for heavy ion recirculators

  • Author

    Deadrick, F.J. ; Barnard, J.J. ; Fessenden, T.J. ; Meridith, J.W. ; Rintamaki, J.

  • Author_Institution
    Lawrence Livermore Nat. Lab., CA, USA
  • Volume
    4
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    2557
  • Abstract
    Work is underway at the Lawrence Livermore National Laboratory to design and build a small-scale, heavy ion recirculating induction accelerator. An essential part of this design work is the development of small non-intercepting diagnostics to measure beam current and position. This paper describes some of this work, with particular emphasis on the development of a small capacitive probe beam position monitor to resolve beam position to the 100 μm level in a 6 cm diameter beam pipe. Initial measured results with an 80 keV potassium ion beam are presented
  • Keywords
    collective accelerators; ion accelerators; particle beam diagnostics; particle beam fusion accelerators; 6 in; 80 keV; ICF driver; Lawrence Livermore National Laboratory; beam current; beam pipe; beam position; beam position monitors; capacitive probe beam position monitor; design work; heavy ion recirculating induction accelerator; heavy ion recirculators; nonintercepting diagnostics; Current measurement; Energy resolution; Ion accelerators; Ion beams; Laboratories; Magnetic fields; Particle beams; Position measurement; Probes; Radio frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505616
  • Filename
    505616