• DocumentCode
    1896567
  • Title

    Beam diagnostic systems and their use in the new IUCF beam line

  • Author

    Jones, W.P. ; Ball, M. ; Collins, J. ; Ellison, T. ; Hamilton, B.

  • Author_Institution
    Cyclotron Facility, Indiana Univ., Bloomington, IN, USA
  • Volume
    4
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    2583
  • Abstract
    Diagnostic tools developed for and being used in a new 30 m beam line (BL1C) connecting the IUCF high intensity polarized ion source (HIPIOS) with the injector cyclotron are described and the results obtained with them are detailed. These devices include non-intercepting beam position monitors, wire scanners, and beam sweeper systems. Studies of rf beam bunching have been performed using a high bandwidth current readout. Programs have been developed for automatic emittance measurements and beam centering in the beam line
  • Keywords
    beam handling equipment; particle beam diagnostics; HIPIOS; IUCF beam line; IUCF high intensity polarized ion source; automatic emittance measurements; beam centering; beam diagnostic systems; injector cyclotron; nonintercepting beam position monitors; Cables; IIR filters; Interference; Linearity; Particle beams; Spinning; Stimulated emission; Time measurement; Turning; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505625
  • Filename
    505625