DocumentCode :
1896612
Title :
Design of the beam profile monitor system for the RHIC injection line
Author :
Witkover, R.L.
Author_Institution :
AGS Dept., Brookhaven Nat. Lab., Upton, NY, USA
Volume :
4
fYear :
1995
fDate :
1-5 May 1995
Firstpage :
2589
Abstract :
A video profile monitor (VPM) system will be used in the AGS-to-RHIC (ATR) transfer line to acquire single bunches transferred at 30 Hz. An array of 12 video cameras will be connected to 4 frame grabbers through a wide-band mux. Fast VME image processing boards will analyze a 120×120 subset of the image, generated by a 4×4 convolution or an ROI computation and sent over the network during the AGS recycle time. Details of the design, results of lab tests and studies with ion and proton beams are presented
Keywords :
ion beams; particle beam diagnostics; proton beams; video cameras; 30 Hz; AGS recycle time; AGS-to-RHIC transfer line; RHIC injection line; beam profile monitor system; fast VME image processing boards; frame grabbers; video profile monitor; Cameras; Computer networks; Convolution; Image analysis; Image generation; Image processing; Monitoring; Recycling; Testing; Wideband;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
Type :
conf
DOI :
10.1109/PAC.1995.505627
Filename :
505627
Link To Document :