DocumentCode
1896683
Title
Preliminary calculations on the determination of APS particle-beam parameters based on undulator radiation
Author
Lumpkin, A. ; Yang, B. ; Chung, Y. ; Dejus, R. ; Voykov, G. ; Dattoli, G.
Author_Institution
Argonne Nat. Lab., IL, USA
Volume
4
fYear
1995
fDate
1-5 May 1995
Firstpage
2598
Abstract
The potential measurement of particle beam emittance at a third-generation synchrotron radiation facility such as the Advanced Photon Source (APS) by characterizing the observed undulator radiation from an insertion device is considered. The nominal APS particle beam parameters have been used in calculations for insertion devices with periods of λ=3.3 cm, λ=5.0 cm (in two configurations), and λ=1.8 cm. The US program, the MDK1F program, and analytical formulae were used. Sensitivity to variations of emittance by 20% from the nominal value are addressed
Keywords
electron accelerators; particle beam diagnostics; synchrotron radiation; undulator radiation; APS particle-beam parameters; Advanced Photon Source; insertion device; particle beam emittance; undulator radiation; Laboratories; Magnetic field measurement; Magnetic flux; Optical coupling; Particle beam measurements; Particle beams; Storage rings; Synchrotron radiation; Thermal management; Undulators;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location
Dallas, TX
Print_ISBN
0-7803-2934-1
Type
conf
DOI
10.1109/PAC.1995.505630
Filename
505630
Link To Document