• DocumentCode
    1897121
  • Title

    CEBAF beam loss accounting

  • Author

    Ursic, R. ; Mahoney, K. ; Hovater, C. ; Hutton, A. ; Sinclair, C.

  • Author_Institution
    Continuous Electron Beam Accel. Facility, Newport News, VA, USA
  • Volume
    4
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    2652
  • Abstract
    This paper describes the design and implementation of a beam loss accounting system for the CEBAF electron accelerator. This system samples the beam current throughout the beam path and measures the beam current accurately. Personnel safety and machine protection systems use this system to turn off the beam when hazardous beam losses occur
  • Keywords
    electron accelerators; machine protection; particle beam diagnostics; CEBAF beam loss accounting; beam current; beam path; electron accelerator; hazardous beam losses; machine protection systems; personnel safety systems; Acceleration; Calibration; Current measurement; Electron accelerators; Electron beams; Particle beams; Permission; Personnel; Protection; Radiation safety;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505648
  • Filename