DocumentCode
1899044
Title
Advanced ultrasound object detection in air by intensive use of side lobes of transducer radiation pattern
Author
Kaniak, Georg ; Schweinzer, Herbert
Author_Institution
Inst. of Electr. Meas. & Circuit Design, Vienna Univ. of Technol., Vienna
fYear
2008
fDate
26-29 Oct. 2008
Firstpage
1092
Lastpage
1095
Abstract
In this paper correlation techniques are discussed to extend the measurement range of an ultrasonic transducer to its side lobes. Broadband coded signals (linear chirps) are used to steer the transducerpsilas radiation pattern. The presented method allows to extend the angle range of the transducer beyond the main lobe for distance measurements and delivers additional information about the angle from the transmitter to the reflecting object.
Keywords
correlation methods; distance measurement; ultrasonic transducers; advanced ultrasound object detection; broadband coded signals; distance measurements; transducer radiation pattern; Acoustic transducers; Brain modeling; Chirp; Electric variables measurement; Frequency; Object detection; Signal resolution; Ultrasonic imaging; Ultrasonic transducers; Ultrasonic variables measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Sensors, 2008 IEEE
Conference_Location
Lecce
ISSN
1930-0395
Print_ISBN
978-1-4244-2580-8
Electronic_ISBN
1930-0395
Type
conf
DOI
10.1109/ICSENS.2008.4716631
Filename
4716631
Link To Document