• DocumentCode
    1899409
  • Title

    W-band radiometer system with switching front-end for multi-load calibration

  • Author

    Weissbrodt, Ernst ; Kallfass, I. ; Hulsmann, A. ; Tessmann, A. ; Leuther, A. ; Massler, Hermann ; Ambacher, Oliver

  • Author_Institution
    Fraunhofer Inst. for Appl. Solid-State Phys. (IAF), Freiburg, Germany
  • fYear
    2011
  • fDate
    24-29 July 2011
  • Firstpage
    3843
  • Lastpage
    3846
  • Abstract
    A W-band Dicke type radiometer with an MMIC single pole-five-throw (SP5T) switch front-end and a Schottky diode detector is presented. The radiometer is intended to test active W-band loads as well as to generate passive millimeter wave imagery. By applying active or conventional hot and cold loads to the spare input ports of the SP5T, the radiometer can switch between the antenna, the external reference loads, and a monolithic integrated 50 Ω load. Hence, accurate radiometric multi-load calibration can be performed as well as standard Dicke operation.
  • Keywords
    Schottky diodes; calibration; microwave switches; millimetre wave detectors; radiometers; MMIC SP5T switch; MMIC single-pole-five-throw switch; Schottky diode detector; W-band Dicke type radiometer system; monolithic integrated load; passive millimeter wave imagery; radiometric multiload calibration; resistance 50 ohm; switching front-end; Calibration; Microwave radiometry; Millimeter wave technology; Noise; Switches; Temperature measurement; MMIC; W-band; active loads; calibration; direct detection; mHEMT; millimeter wave switch; radiometer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Geoscience and Remote Sensing Symposium (IGARSS), 2011 IEEE International
  • Conference_Location
    Vancouver, BC
  • ISSN
    2153-6996
  • Print_ISBN
    978-1-4577-1003-2
  • Type

    conf

  • DOI
    10.1109/IGARSS.2011.6050069
  • Filename