Title :
Beam transfer function and transverse impedance measurements in the Fermilab Main Ring
Author :
Chou, P.J. ; Jackson, G.
Author_Institution :
Fermi Nat. Accel. Lab., Batavia, IL, USA
Abstract :
Knowledge of the Main Ring impedance is crucial for the understanding of beam instabilities. Beam transfer function measurements provide a direct measurement of beam impedance. With proper calibration procedures, values for the transverse impedances can be extracted from beam transfer function measurements. The principle of measurements is reviewed and results are presented
Keywords :
particle beam diagnostics; particle beam stability; proton accelerators; synchrotrons; Fermilab Main Ring; beam instabilities; beam transfer function; beam transfer function measurements; transverse impedance measurements; Equations; Feedback; Frequency; Impedance measurement; Monitoring; Particle beams; Position measurement; Stability; Transfer functions; Voltage;
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
DOI :
10.1109/PAC.1995.505793