• DocumentCode
    1901873
  • Title

    Detection of stator slot magnetic wedge failures for induction motors without disassembly

  • Author

    Kun Wang Lee ; Jongman Hong ; Doosoo Hyun ; Sang Bin Lee ; Wiedenbrug, Ernesto Jorge ; Teska, Mike ; Chaewoong Lim

  • Author_Institution
    Dept. of Electr. Eng., Korea Univ., Seoul, South Korea
  • fYear
    2013
  • fDate
    27-30 Aug. 2013
  • Firstpage
    183
  • Lastpage
    191
  • Abstract
    The recent trend in large ac machines is to employ magnetic stator slot wedges for improving the motor efficiency, power factor, and power density. The mechanical strength of magnetic wedges is weak compared to the epoxy glass wedges, and many cases of loose and missing wedges have recently been increasingly reported. Magnetic wedge failure deteriorates the performance and reliability of the motor, but there is no method available for testing the wedge quality other than visual inspection after rotor removal. Monitoring of overall wedge condition without motor disassembly can help reduce the cost of maintenance and risk of degradation in performance. In this paper, a new off-line standstill test method for detecting magnetic wedge problems for ac machines without motor disassembly is proposed. An experimental study on 380 V, 5.5 kW and 6.6 kV, 3.4 MW motors with magnetic wedges is performed to verify the effectiveness of the new test method. It is shown that the new method can provide reliable monitoring of magnetic wedge problems over time, independent of other faults or motor design.
  • Keywords
    condition monitoring; fault diagnosis; induction motors; machine testing; magnetic devices; maintenance engineering; risk management; stators; ac machines; induction motors; magnetic stator slot wedges; maintenance cost reduction; mechanical strength; motor efficiency improvement; motor reliability; overall wedge condition monitoring; power 3.4 MW; power 5.5 kW; power density improvement; power factor improvement; risk cost reduction; rotor removal; stator slot magnetic wedge failure detection; visual inspection; voltage 380 V; voltage 6.6 kV; Induction motors; Magnetic cores; Magnetic flux; Rotors; Stator windings; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED), 2013 9th IEEE International Symposium on
  • Conference_Location
    Valencia
  • Type

    conf

  • DOI
    10.1109/DEMPED.2013.6645715
  • Filename
    6645715