DocumentCode :
1901895
Title :
Selective harmonic current mitigation with a Shunt Active Power Filter
Author :
Cleary-Balderas, L.A. ; Medina-Rios, A.
Author_Institution :
Div. de Estudios de Posgrado, Univ. Michoacana de San Nicolas de Hidalgo, Morelia, Mexico
fYear :
2012
fDate :
9-11 Sept. 2012
Firstpage :
1
Lastpage :
5
Abstract :
This paper proposes a Shunt Active Power Filter (SAPF) for harmonic mitigation based a selective harmonic current mitigation (SHCM) method. The proposed SHCM method improves the filtering efficiency and solves many issues existing in highly contaminated loads. The Fast Fourier Transform (FFT) is applied to a specific harmonic current detection of a three-phase circuit. A simulation study of a three-phase compensated system is carried out using Matlab/Simulink® to validate the proposed method.
Keywords :
active filters; fast Fourier transforms; power harmonic filters; FFT; Matlab-Simulink simulation; SAPF; SHCM method; fast Fourier transform; harmonic current detection; selective harmonic current mitigation method; shunt active power filter; three-phase compensation circuit system; Active filters; Discrete Fourier transforms; Harmonic analysis; Inverters; Power harmonic filters; Time frequency analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
North American Power Symposium (NAPS), 2012
Conference_Location :
Champaign, IL
Print_ISBN :
978-1-4673-2306-2
Electronic_ISBN :
978-1-4673-2307-9
Type :
conf
DOI :
10.1109/NAPS.2012.6336419
Filename :
6336419
Link To Document :
بازگشت