DocumentCode
1902219
Title
The effect of coupling on luminosity [storage rings]
Author
Sagan, David
Author_Institution
Lab. of Nucl. Studies, Cornell Univ., Ithaca, NY, USA
Volume
5
fYear
1995
fDate
1-5 May 1995
Firstpage
3382
Abstract
In a storage ring the existence of skew quadrupoles, solenoids, and other coupling elements breaks the independence of the horizontal and vertical motions. With the flat beams used in electron/positron colliding beam storage rings this coupling results in an increase in the vertical beam size with an attendant loss in luminosity. By defining a `badness´ parameter Bc the luminosity loss can be directly related to measurements of the coupling
Keywords
colliding beam accelerators; electron accelerators; particle beam diagnostics; particle beam dynamics; storage rings; badness parameter; coupling; electron/positron storage rings; flat beams; luminosity; skew quadrupoles; solenoids; vertical beam size; Computer simulation; Degradation; Extraterrestrial measurements; Laboratories; Loss measurement; Optical coupling; Particle beams; Solenoids; Storage rings; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location
Dallas, TX
Print_ISBN
0-7803-2934-1
Type
conf
DOI
10.1109/PAC.1995.505889