DocumentCode
1908584
Title
Plant-wide temperature drop monitoring in run-out table strip cooling process
Author
Zheng, Yi ; Li, Shaoyuan
Author_Institution
Dept. of Autom., Shanghai Jiao Tong Univ., Shanghai, China
fYear
2011
fDate
23-26 May 2011
Firstpage
287
Lastpage
292
Abstract
Since the strip transient temperature can only be measured at a few positions inside the cooling section in hot-rolled strip laminar cooling process, a new approach of monitoring strip transient temperature in cooling process is proposed. A simple and accurate state space representation is designed firstly to describe the temperature drop of strip. An Extended Kalman Filter (EKF) is designed to reconstruct the strip temperature distribution because of its simple designation. Considering coordinating the convergence rate and stability, a trade-off feed-back coefficient of EKF is chosen. The reliability of the proposed method was demonstrated by the experimentation in one steel Ltd.
Keywords
Kalman filters; cooling; finite difference methods; steel industry; temperature; extended Kalman filter; feedback coefficient; hot-rolled strip laminar cooling process; one steel limited; plant-wide temperature drop monitoring; run-out table strip cooling process; strip temperature distribution; strip transient temperature monitoring; Cooling; Monitoring;
fLanguage
English
Publisher
ieee
Conference_Titel
Advanced Control of Industrial Processes (ADCONIP), 2011 International Symposium on
Conference_Location
Hangzhou
Print_ISBN
978-1-4244-7460-8
Electronic_ISBN
978-988-17255-0-9
Type
conf
Filename
5930440
Link To Document