DocumentCode :
1908806
Title :
On the mechanisms of differential-mode to common-mode conversion in the broadband over power line (BPL) frequency band
Author :
Vukicevic, Ana ; Rubinstein, Marcos ; Rachidi, Farhad ; Bermudez, José-Luis
Author_Institution :
EMC Group, Swiss Fed. Inst. of Technol., Lausanne
fYear :
2006
fDate :
Feb. 27 2006-March 3 2006
Firstpage :
658
Lastpage :
661
Abstract :
The conversion between the common and the differential modes is of great importance in the transmission of data over poorly balanced cables such as electrical wiring. In this paper, we have studied some of the mechanisms involved in this conversion, both experimentally and theoretically. The results show that along-the-line variations in the line parameters be it gradual or abrupt, are responsible for part of the common mode in electric cables. Asymmetries at the source are also responsible for part of the common mode conversion and they can be dominant in certain cases
Keywords :
broadband networks; carrier transmission on power lines; power cables; broadband; common-mode conversion; differential-mode; electric cables; line parameters; power line frequency band; Broadband communication; Cables; Circuits; Conducting materials; Delta modulation; Electromagnetic compatibility; Frequency conversion; Modems; Power line communications; Wiring;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2006. EMC-Zurich 2006. 17th International Zurich Symposium on
Conference_Location :
Singapore
Print_ISBN :
3-9522990-3-0
Type :
conf
DOI :
10.1109/EMCZUR.2006.215020
Filename :
1629710
Link To Document :
بازگشت