Abstract :
Summary form only given. Efficient, high-power millimeter-wave sources are needed in electron cyclotron heating (ECH) for many present and future fusion experiments. CPI, in collaboration with the National Institute of Fusion Sciences, Japan, is developing high-power, CW gyrotrons with an internal converter at 84 GHz for ECH in the Large Helical Device (LHD) Heliotron. The first prototype of this kind of tube has been tested to long pulse and 200 kW, CW. The second prototype has been fabricated and is currently being tested at CPI. In addition to the improved cooling and vacuum pumping capability of the present tube, it is designed to operate with a single stage depressed collector.
Keywords :
gyrotrons; millimetre wave tubes; plasma radiofrequency heating; stellarators; 1 MW; 200 kW; 50 A; 80 kV; 84 GHz; Large Helical Device Heliotron; cooling; electron cyclotron heating; fusion experiments; gyrotron; high-power CW gyrotrons; high-power millimeter-wave sources; internal converter; single-stage depressed collector operation; vacuum pumping; Cooling; Electrons; Gyrotrons; Laser theory; Optical pulse shaping; Prototypes; Pulse amplifiers; Testing; Undulators; X-ray lasers;