DocumentCode
191379
Title
A 7 GHz Biosensor for permittivity change with enhanced sensitivity through phase compensation
Author
Wessel, Jan ; Schmalz, Klaus ; Meliani, Chafik ; Cahill, Brian ; Scheytt, J. Christoph
Author_Institution
IHP, Frankfurt (Oder), Germany
fYear
2014
fDate
6-9 Oct. 2014
Firstpage
699
Lastpage
702
Abstract
A calibration technique as well as measurement results for a 7 GHz Biosensor are presented. It is shown that the applied sensor structure can be calibrated by adjusting the phase of a sensing element´s transmission S21. This is realized by slowing down the wave traveling a microstrip line serving as a reference in the differential sensor structure. The dielectric properties along with certain physical boundaries of an obstacle covering parts of the microstrip line evoke that effect. Measurements with an ethanol serious along with simulation results showed that sensitivity can be increased substantially with this calibration technique. A change of the real part of the sample´s permittivity of 48 leads to a 18 MHz frequency shift.
Keywords
bioelectric phenomena; biosensors; calibration; microsensors; microstrip lines; permittivity; calibration; dielectric properties; differential sensor structure; element transmission S21; ethanol; frequency 7 GHz; microstrip line; permittivity; phase compensation; physical boundaries; Ethanol; Gain measurement; Microstrip; Polymers; Radio frequency; Sensitivity; Sensors; Biosensor; Calibration; Contactless; Label-free; Phase Detection;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference (EuMC), 2014 44th European
Conference_Location
Rome
Type
conf
DOI
10.1109/EuMC.2014.6986530
Filename
6986530
Link To Document