DocumentCode :
1914007
Title :
Ethanol fuel analysis by Time-Domain Reflectometry
Author :
Rodrigues, Daniel B. R. ; Peres, Henrique E. M. ; Becari, Wesley
Author_Institution :
Lab. de Microeletronica, Escola Politec. da USP, Sao Paulo, Brazil
fYear :
2013
fDate :
4-7 Aug. 2013
Firstpage :
1
Lastpage :
3
Abstract :
The technique of Time Domain Reflectometry (TDR) is applied for qualifying ethanol adulterated with water and / or methanol. We used the commercial TDR model VG400, which was originally developed for determining soil moisture, making this study an original approach for qualifying fuels. Several samples of alcohol with the addition of its main contaminants (water and methanol) were prepared and measured with the TDR sensor. The results indicate good response linearity, showing the TDR technique is a promising technique for fuel qualification.
Keywords :
fuel; nondestructive testing; optical sensors; quality control; time-domain reflectometry; TDR model VG400; TDR sensor; contaminants; ethanol adulteration; ethanol fuel analysis; fuel qualification; methanol; time-domain reflectometry; water; Ethanol; Fuels; Moisture measurement; Pollution measurement; Qualifications; Reflectometry; Fuel Qualification; TDR; Time-Domain Reflectometry;