Abstract :
Geometric accuracy of a close-range photogrammetric system is assessed in this paper considering surface reconstruction with structured light as its main purpose. The system is based on an off-the-shelf digital camera and a pattern projector. The mathematical model for reconstruction is based on the parametric equation of the projected straight line combined with collinearity equations. A sequential approach for system calibration was developed and is presented. Results obtained from real data are also presented and discussed. Experiments with real data using a prototype have indicated 0.5 mm of accuracy in height determination and 0.2 mm in the XY plane considering an application where the object was 1630 mm distant from the camera
Keywords :
calibration; cameras; image processing equipment; image reconstruction; photogrammetry; accuracy assessment; close-range photogrammetric system; collinearity equations; digital camera; geometric accuracy; image surface reconstruction; mathematical model; parametric equation; pattern projector; projected straight line; structured light; system calibration; Calibration; Digital cameras; Electrical capacitance tomography; Equations; Image reconstruction; Mathematical model; Prototypes; Read only memory; Shape measurement; Surface reconstruction;
Conference_Titel :
Computer Graphics, Image Processing, and Vision, 1998. Proceedings. SIBGRAPI '98. International Symposium on
Conference_Location :
Rio de Janeiro
Print_ISBN :
0-8186-9215-4
DOI :
10.1109/SIBGRA.1998.722732