DocumentCode
1921548
Title
Determination of Absorption Properties of Separators in Lead-Acid Storage Batteries
Author
Dzenzerskiy, V.A. ; Sokolovskiy, I.I. ; Plaksin, S.V. ; Pogorelaya, L.M.
Author_Institution
Ukraine NAS Transmag, Dnepropetrovsk
fYear
2007
fDate
10-14 Sept. 2007
Firstpage
760
Lastpage
762
Abstract
Presented in this paper are the results of creation of radiophysical method for separators hydrophily definition. The method is based on determination of electrolyte volume content in separator from the value of microwave signal attenuation as a consequence of separator insertion into microwave transmission line. High accuracy is achieved using specific equipment implementation: bridge method and high stability of sounding radiation frequency provided by temperature-compensated semiconductor self-oscillator with high-Q reference resonators, and also due to special diodes interconnection, providing minimum modulation sensitivity.
Keywords
absorption; compensation; electrolytes; microwave oscillators; resonators; secondary cells; semiconductor diodes; sensitivity; bridge method; diodes interconnection; electrolyte volume content; high-Q reference resonators; hydrophily definition; lead-acid storage batteries; microwave signal attenuation; microwave transmission line; modulation sensitivity; radiophysical method; separator absorption properties; temperature-compensated semiconductor self-oscillator; Attenuation; Batteries; Bridges; Electromagnetic wave absorption; Frequency; Microwave devices; Microwave theory and techniques; Particle separators; Stability; Transmission lines;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave & Telecommunication Technology, 2007. CriMiCo 2007. 17th International Crimean Conference
Conference_Location
Crimea
Print_ISBN
978-966-335-012-7
Type
conf
DOI
10.1109/CRMICO.2007.4368933
Filename
4368933
Link To Document