DocumentCode
1921802
Title
Reconstruction of Non-uniformly Sampled Signal after Time-Interleaved ADCS using Transposed Farrow Structure
Author
Babic, Djordje
Author_Institution
Inst. of Commun. Eng., Tampere Univ. of Technol.
Volume
2
fYear
2005
fDate
21-24 Nov. 2005
Firstpage
1622
Lastpage
1625
Abstract
This paper considers the problem of correcting time-skew errors in time-interleaved analog-to-digital converter systems (TI ADC). The reconstruction of the uniform sequence and correction of the time-skew error is done by using polynomial-based interpolation filter implemented as transposed Farrow structure. The main advantages of the proposed reconstruction system are higher flexibility and reduced number of multipliers. The system is highly flexible and allows output sampling rate that is independent of the sampling rate of each subconverter of TI ADC system
Keywords
analogue-digital conversion; filtering theory; interpolation; polynomials; signal reconstruction; signal sampling; polynomial-based interpolation filter; sampled signal reconstruction; sampling rate; time-interleaved analog-to-digital converter systems; time-skew errors; transposed Farrow structure; Analog-digital conversion; Circuits; Delay; Distortion; Error correction; Filters; Interpolation; Polynomials; Sampling methods; Signal resolution;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer as a Tool, 2005. EUROCON 2005.The International Conference on
Conference_Location
Belgrade
Print_ISBN
1-4244-0049-X
Type
conf
DOI
10.1109/EURCON.2005.1630280
Filename
1630280
Link To Document