DocumentCode :
1922203
Title :
Prospect of Using The Photoneutron Beam Component from High Energy linacs in BNCT, A Monte Carlo Simulation
Author :
Alfuraih, A. ; Alghamdi, A.A. ; Ma, A. ; Spyrou, N.M.
Author_Institution :
Dept. of Phys., Surrey Univ., Guildford
Volume :
2
fYear :
2005
fDate :
21-24 Nov. 2005
Firstpage :
1703
Lastpage :
1705
Abstract :
One drawback in widely using neutron capture therapy (NCT) is the limited number of appropriate neutron source facilities. At present neutron sources for clinical NCT are mainly research reactors. However most reactors are not in close proximity to hospitals and their use for clinical trials can be difficult. Other suggested sources include dedicated single-purpose reactors, accelerator-based neutron sources and 252Cf isotopic sources. This study examines the potential of using the photoneutrons produced from medical linacs, which are embedded in hospital environments for radiotherapy, as a source for NCT. Preliminary simulation using MCNPX simulation were conducted to calculate the photoneutron flux of a medical linac head with the aim of maximizing the thermal and epithermal neutron component whilst minimizing the photon contribution from the primary beam. Further simulations were conducted to determine the most feasible conditioning methods. Target desirable minimum neutron beam fluence rate should be 10 9 cm-2 s-1 according to IAEA guidelines. Although beams of 5 times 108 cm-2 s -1 are useable, they result in rather long irradiation times as current experience show. In existing facilities the range of dose from epithermal neutrons is from 2.5 to 13 times 10-13 Gy cm2 per neutron. A target value should be 2 times 10-13 Gy cm2 per epithermal neutron. The goal of this work was to produce neutrons that meet these treatment conditions
Keywords :
Monte Carlo methods; neutron beams; neutron capture therapy; neutron sources; Monte Carlo simulation; accelerator-based neutron sources; boron neutron capture therapy linac; dedicated single-purpose reactors; epithermal neutron; high energy linacs; linear accelerator; photoneutron beam component; photoneutrons; Acceleration; Clinical trials; Head; Hospitals; Inductors; Linear accelerators; Medical simulation; Neutron capture therapy; Particle beams; Thermal conductivity; BNCT; Boron Neutron Capture Therapy Linac; linear accelerator;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computer as a Tool, 2005. EUROCON 2005.The International Conference on
Conference_Location :
Belgrade
Print_ISBN :
1-4244-0049-X
Type :
conf
DOI :
10.1109/EURCON.2005.1630301
Filename :
1630301
Link To Document :