• DocumentCode
    1926427
  • Title

    An improved method for void-fraction measurement using gamma-transmission gauge

  • Author

    Wang, Tien-Ko ; Liu, Hong-Ming

  • Author_Institution
    Dept. of Nucl. Eng., Nat. Tsing Hua Univ., Hsinchu, Taiwan
  • fYear
    1992
  • fDate
    25-31 Oct 1992
  • Firstpage
    67
  • Abstract
    A simple ring model is proposed which, in conjunction with a previously developed iterative procedure, can correct for the void-distribution effect in void-fraction determination. This method has been tested by a series of benchmark experiments. The results show that the accuracies of void-fraction predictions can be within ±10%. The proposed model is especially useful when the void distribution in a two-phase-flow system is not known
  • Keywords
    fission reactor cooling and heat recovery; radiation monitoring; benchmark experiments; gamma-transmission gauge; two-phase-flow; void-fraction measurement; Accuracy; Benchmark testing; Drilling; Gamma ray detection; Gamma ray detectors; Iterative methods; Measurement units; Phase measurement; Solids; Statistical distributions;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1992., Conference Record of the 1992 IEEE
  • Conference_Location
    Orlando, FL
  • Print_ISBN
    0-7803-0884-0
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1992.301154
  • Filename
    301154