DocumentCode
1927699
Title
PMTs of superior time resolution, wide dynamic range, and low cross-talk, multi-anode PMTs
Author
Suzuki, Seiji ; Nakaya, Takanori ; Suzuki, Atsuhide ; Suzuki, Hiroyuki ; Yoshioka, Kesamitsu ; Yoshizawa, Yuji Yoshi
Author_Institution
Hamamatsu Photonics K.K., Shizuoka, Japan
fYear
1992
fDate
25-31 Oct 1992
Firstpage
299
Abstract
The authors describe a new type of photomultiplier tube (PMT) with fine mesh (FM) dynodes which have exceptional performance in time response and linearity with high gain even under magnetic fields. The PMTs are available not only as a conventional single-anode but also as multi-anode read-outs with very low cross-talk. These FM PMTs show promise as detectors of scintillation and Cerenkov light
Keywords
photomultipliers; Cerenkov light; cross-talk; fine mesh dynodes; high gain; multi-anode; photomultiplier tube; scintillation; time response; Anodes; Detectors; Dynamic range; Electrons; Linearity; Magnetic fields; Magnetic flux; Magnetic flux density; Performance gain; Time factors;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference, 1992., Conference Record of the 1992 IEEE
Conference_Location
Orlando, FL
Print_ISBN
0-7803-0884-0
Type
conf
DOI
10.1109/NSSMIC.1992.301233
Filename
301233