DocumentCode :
1929358
Title :
Study on measuring method of thrombolyses for wire type stirrer
Author :
Morita, Minoru ; Ajoudanian, Mohammad ; Suzuki, Michiyasu ; Jiang, Zhongwei
Author_Institution :
Dept of Mech. Eng., Yamaguchi Univ., Ube, Japan
fYear :
2011
fDate :
9-11 May 2011
Firstpage :
9
Lastpage :
12
Abstract :
A cerebral thrombus or blood clot might cause cerebral stroke and even decease if the clot could not be dissolved within several hours after it was formed. This paper presents a fundamental study on development of a new type of mechanical micro stirrer for assisting the dissolution of the thrombus with a few amount of thrombolytic agent. The micro stirrer is made of a simple structure with a piezoelectric. An efficient excitation method for stirring up the thrombus to get a quick dissolution is investigated. Furthermore, to evaluate the dissolution state in vivo, the method using the stirrer as both the stimulator to beat the clot and the probe to evaluate its solubility is proposed.
Keywords :
biomedical transducers; blood vessels; brain; catheters; dissolving; patient treatment; piezoelectric transducers; solvation; bending catheter; cerebral stroke; cerebral thrombus; clinical treatments; mechanical micro stirrer; piezoelectric; thrombolyses; thrombolytic agent; wire type stirrer; Catheters; Continuous wavelet transforms; Shape; Time frequency analysis; Wavelet analysis; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Systems, Signal Processing and their Applications (WOSSPA), 2011 7th International Workshop on
Conference_Location :
Tipaza
Print_ISBN :
978-1-4577-0689-9
Type :
conf
DOI :
10.1109/WOSSPA.2011.5931428
Filename :
5931428
Link To Document :
بازگشت