Abstract
Modelling of medium-frequency power transformers is analyzed and experimentally validated to characterize these devices along the operating power range. Special attention is paid to the core losses, winding losses and thermal modelling at operating conditions typical of power electronics applications. The performance of a commercial 50 kHz-5 kVA litz-wired transformer for PV resonant converters is characterized and tested by means of a specific measurement procedure. A complete model is selected from the estimated and measured results. Finally, this model is applied to improve the design of the commercial transformer previously analyzed in order to match typical PV requirements such as a high efficiency at different irradiation levels.
Keywords
cores; invertors; losses; photovoltaic power systems; power transformers; transformer windings; PV inverters; PV resonant converters; apparent power 5 kVA; commercial transformer; core losses; frequency 50 kHz; litz-wired transformer; measurement procedure; medium-frequency power transformers; power electronics applications; thermal modelling; typical PV requirements; winding losses; Conductors; Core loss; Loss measurement; Power transformers; Temperature measurement; Windings; Wires;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2013 IEEE
Conference_Location
Denver, CO
Type
conf
DOI
10.1109/ECCE.2013.6647284
Filename
6647284
Link To Document