DocumentCode
1934661
Title
Early detection technique for stator winding inter-turn fault in BLDC motor using input impedance
Author
Chae-Lim Jeong ; Seung-Tae Lee ; Jin Hur
Author_Institution
Dept. of Electr. Eng., Univ. of Ulsan, Ulsan, South Korea
fYear
2013
fDate
15-19 Sept. 2013
Firstpage
4453
Lastpage
4459
Abstract
This paper proposes an early diagnosis technique for the inter-turn fault (ITF) in the stator winding in a brushless DC (BLDC) motor using the input impedance. We have analyzed the varying characteristics owing to the ITF through various experiments and simulation. As a result, we have presented a simple method for fault detection. This technique can be applied without requiring a fast Fourier transform (FFT) and the calculation of the negative-sequence impedance. The fault detection system works on the basis of the comparison of the measured impedance with the database impedance. The variations in the characteristics owing to the ITF as well as the proposed technique have been verified through the simulation and the experiment.
Keywords
brushless DC motors; fault diagnosis; stators; BLDC motor; ITF; brushless DC motor; database impedance; early detection technique; fault detection system; input impedance; negative-sequence impedance; stator winding inter-turn fault; Brushless motors; Circuit faults; Impedance; Inductance; Steady-state; Synchronous motors; Windings;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2013 IEEE
Conference_Location
Denver, CO
Type
conf
DOI
10.1109/ECCE.2013.6647296
Filename
6647296
Link To Document