DocumentCode
1935143
Title
Experimental results of the pulsed digital oscillator for MEMS in undersampling conditions
Author
Pons, Joan ; Ricart, Jordi ; Domínguez, Manuel
Author_Institution
Departament d´´Enginyeria Electronica, Univ. Politecnica de Catalunya, Barcelona, Spain
fYear
2005
fDate
2-4 Feb. 2005
Firstpage
469
Lastpage
472
Abstract
This paper describes experimental work and results showing that the PDO, a set of sigma-delta based oscillator structures for MEMS recently introduced by the authors, can also maintain a good oscillation behaviour for sampling frequencies under the Nyquist limit. So, it can work in undersampling conditions and an extension of the use of this kind of structures to higher frequency applications becomes possible.
Keywords
feedback oscillators; micromechanical resonators; sigma-delta modulation; signal sampling; MEMS; Nyquist limit; PDO; oscillation; pulsed digital oscillator; sigma-delta based oscillator; undersampling condition; Damping; Delta-sigma modulation; Fractals; Microelectromechanical devices; Micromechanical devices; Oscillators; Resonant frequency; Sampling methods; Shape; Topology;
fLanguage
English
Publisher
ieee
Conference_Titel
Electron Devices, 2005 Spanish Conference on
Conference_Location
Tarragona
Print_ISBN
0-7803-8810-0
Type
conf
DOI
10.1109/SCED.2005.1504484
Filename
1504484
Link To Document