DocumentCode :
1935143
Title :
Experimental results of the pulsed digital oscillator for MEMS in undersampling conditions
Author :
Pons, Joan ; Ricart, Jordi ; Domínguez, Manuel
Author_Institution :
Departament d´´Enginyeria Electronica, Univ. Politecnica de Catalunya, Barcelona, Spain
fYear :
2005
fDate :
2-4 Feb. 2005
Firstpage :
469
Lastpage :
472
Abstract :
This paper describes experimental work and results showing that the PDO, a set of sigma-delta based oscillator structures for MEMS recently introduced by the authors, can also maintain a good oscillation behaviour for sampling frequencies under the Nyquist limit. So, it can work in undersampling conditions and an extension of the use of this kind of structures to higher frequency applications becomes possible.
Keywords :
feedback oscillators; micromechanical resonators; sigma-delta modulation; signal sampling; MEMS; Nyquist limit; PDO; oscillation; pulsed digital oscillator; sigma-delta based oscillator; undersampling condition; Damping; Delta-sigma modulation; Fractals; Microelectromechanical devices; Micromechanical devices; Oscillators; Resonant frequency; Sampling methods; Shape; Topology;